Replies Archived Message
Posted by Tony Sefton. on February 18, 2004, 7:50 pm, in reply to "Re: peugeot 406 t/d 1997 1.9 Fan on all the time"
Hi Dave , you can't disconnect sensors on this one to stop the fans, as soon as you disconnect the sensor, it makes the fans run all the time, the sensor is a 2 pin one on the thermostat housing, If they go off when the ignition is turned off, supect sensor, bitron or wiring, and if they stop on with ignition turned off, suspect faulty relay's behind grill.
|
Message Thread:
- Peugeot 406 TD 1997 1.9 Cooling fan runs all the time with ignition on - david jackson February 18, 2004, 1:00 pm
- Replies - Peter Warman February 18, 2004, 4:00 pm
- Replies - Peter Cooper February 18, 2004, 4:40 pm
- Replies - d jackson February 18, 2004, 5:52 pm
- Replies - Sean Mc Gettigan February 18, 2004, 7:41 pm
- Replies - Tony Sefton. February 18, 2004, 7:50 pm
- Replies - John Davison February 18, 2004, 8:24 pm
- Replies - Job February 19, 2004, 7:43 am
- Replies - D Jackson February 19, 2004, 7:05 pm
|
|