    1 Fault code from Sykes MAP -
    ""1218 Needle Lift Sensor Circuit, SRC Above Upper Limit.""

    The DTC will not clear, have looked at the loom around the pump and it doesnt seem to be chaffing on anything, Going to strip it down more tommorow.

    When it is left overnight or for a few hours (Cold), it will not start,

    When car is warm, It starts first time no problem,


    Plugs have been changed, and there is power from Relay,

    There is fuel to the injectors,(but dont possess a FPG so dont know if pressure is correct.

    Strange thing(i think) if you bump it it starts, and then will start all day no problem,

    Should i concentrate on the DTC or is the pump goosed

    Thanks
    Mick