    Renault Megane 2002 1.9 DTi eng.code F9Q 744 - Non starter, cut out twice then non start Archived Message

    Posted by Jim watson on November 15, 2005, 5:29 pm

    Hi all, looking at this car for one of the garages I do work for, was towed in as a non-starter Apparently it had cut out once or twice with the owner but restarted then eventually it wouldn't. Only code it has is in the memory is "thermoplunger relay N,open or short circuit to earth", also tried a new crank sensor just to eliminate it, however when you crank it it is incredibly close to starting, just won't go that last bit, any ideas please?

    Message Thread:

    • Renault Megane 2002 1.9 DTi eng.code F9Q 744 - Non starter, cut out twice then non start - Jim watson November 15, 2005, 5:29 pm
      • replies - MARK PARKINSON November 15, 2005, 6:53 pm
        • replies - Jim Watson November 16, 2005, 6:39 pm
          • fixed - Jim watson December 15, 2005, 11:19 am